BuildMetricLab

Sustainability & Green Build

Window Energy Savings Calculator

Estimates heating energy saved by a window replacement from the U-value improvement

Updated October 13, 2026 · Live

What this tool does

Estimates the annual heat lost through the glass that a window replacement removes, from the glazed area, the existing and new U-values and your heating season, with the cost and CO₂ at your fuel price and factor and the fuel a 90% boiler or furnace burns for it.

Enter the glazed area, the existing and new U-values and your heating season; the calculator returns the annual heat-loss reduction, the cost and CO₂ saved at your fuel price and factor, and the fuel equivalent at 90% heating efficiency.

Inputs
ft²
BTU/h·ft²·°F
BTU/h·ft²·°F
°F
hrs
$/therm
lb/therm
Result

Annual Heat-Loss Reduction

151 therms/yr (4,411 kWh)

Cost Saving
$225.75 at the fuel price, before heating efficiency
CO₂ Avoided
1,761 lb/yr at the fuel factor, before heating efficiency
At 90% Heating Efficiency
167 therms/yr (4,901 kWh) of fuel, $250.83 and 1,957 lb/yr (a condensing boiler or furnace)
U-value Change
1.000 BTU/h·ft²·°F → 0.300 BTU/h·ft²·°F (70% less loss through the glass)
Area
215.0 ft²
Season Assumed
4,167 °F·days (25 °F × 4,000 h ÷ 24)
Plain Estimate
From BrightScale Labs
Invoice maker
Quote at the door. Signed on the spot.
Estimates and invoices for trades, built while you are still in the room.
Scan to get
Get it onGoogle Play

People also use

Formula Used
E=(U0−U1)⋅A⋅ΔT⋅h1000E = \frac{(U_0 - U_1) \cdot A \cdot \Delta T \cdot h}{1000}
EE
Annual heat-loss reduction
U0U_0
Existing U-value
U1U_1
New U-value
AA
Total glazed area
ΔT\Delta T
Temperature difference
hh
Heating hours per year

How the window energy savings calculator works

Heat conducts through a window at a rate set by its U-value, so over a heating season the loss through the glass is U × area × temperature difference × hours. Replace the glass with a lower U-value and the heat you no longer lose is the difference: (Uexisting − Unew) × area × ΔT × hours, divided by 1,000 to turn watt-hours into kilowatt-hours. The calculator prices that heat at your fuel rate and converts it to CO₂ with your fuel factor, both before heating efficiency, and then shows what the same saving looks like once a 90% boiler or furnace is burning fuel to make it, which is 11% more of everything.

With the US defaults, 215 ft² of single-pane glass at a U-factor of 1.0 replaced by low-E double-pane at 0.30, over 4,000 heating hours at an average 25 °F indoor-to-outdoor difference, cuts the heat lost through the glass by 151 therms (4,411 kWh) a year: $226 at $1.50 a therm and about 1,761 lb of CO₂, or 167 therms, $251 and 1,957 lb once a 90% furnace has made the heat. The metric defaults are a smaller job: 20 m² going from 3.0 to 1.4 W/m²K over 2,000 hours at 12 °C saves 768 kWh, £61 at 8p, and 141 kg of CO₂, or 853 kWh, £68 and 156 kg through a 90% boiler. The arithmetic is the same on both sides of the unit switch; only the conversions differ, at 5.678 W/m²K per BTU/h·ft²·°F and 29.3 kWh per therm.

Typical window U-values and what they save

The U-value is the whole of the window input, so where you start matters more than where you finish. In North America the whole-window U-factor is printed on the NFRC label in BTU/h·ft²·°F, and the US Department of Energy's consumer guide to energy-efficient windows puts the usual range at 0.20 to 1.20: single clear glass near 1.0, older clear double-pane near 0.48, low-E double-pane 0.25 to 0.30, triple-pane 0.15 to 0.22. Europe, the UK and Australia quote the same property in W/m²K, with single glazing around 5.8, 1980s double glazing 2.8, current double glazing 1.2 to 1.4 and triple glazing 0.8 or better; England's limit for replacement windows in existing homes is 1.4 W/m²K or a Window Energy Rating of Band B (Approved Document L, Table 4.2), which is 0.25 in US units. The default US step from 1.0 to 0.30 removes 70% of the conduction through the glass; the same 215 ft² going from a good double-pane at 0.48 to 0.30 removes 38% and saves 39 therms rather than 151, and 120 ft² of that glass over a milder 2,000-hour, 15 °F season saves 6.5 therms, about $13.

What this tool does not do

It models conduction through the glazed area only. It leaves out air leakage, which old sashes add and new units remove and which is often the larger saving in practice, solar gain in either direction, frames and spacers beyond what the whole-window U-value already blends in, and any cooling saving in summer. It does not know your climate, so the temperature difference and heating hours are yours to set, and their product is the whole of the climate input. It does not price the windows, so there is no payback here; the triple-pane savings calculator adds an installed cost and a payback for the same physics. And it does not say whether a window U-value meets your building code, which depends on where you live.

On-site considerations for window energy savings

The temperature difference is an average across the hours the heating runs, not the coldest night, and multiplied by the heating hours and divided by 24 it is the heating degree-days that climate data is published in. The calculator shows that figure: the US defaults equal 4,167 °F·days and the metric defaults 1,000 °C·days. If you know your local degree-days to a base near your indoor temperature, set the hours and the difference so their product ÷ 24 lands on it. Measure the glazed area window by window on the frame and add it up; a house with 215 ft² (20 m²) of glass is typical of a small to medium home, and the saving scales exactly with it. For a heat pump, the 90% row does not apply; the heat basis is right if you then divide by the seasonal coefficient of performance yourself.

Codes and compliance

Window U-values are regulated almost everywhere and the limits differ by region. In England, Approved Document L (2021 edition, 2023 amendments) caps replacement windows in existing dwellings at 1.4 W/m²K or Band B. In the US the International Energy Conservation Code sets maximum fenestration U-factors by climate zone, adopted by most states with amendments, and ENERGY STAR window certification is zoned too. Australia's National Construction Code and Canada's provincial codes and ENERGY STAR criteria do the same in their own units. None of them change the arithmetic here, but the new U-value you enter has to meet whichever applies to you.

Before you order

Read the U-value off the label or datasheet of the actual unit, whole-window rather than centre-of-glass, and take the existing one from the old unit's label if it still has one or from the typical figures above. Take the fuel price from a recent bill rather than a tariff headline, and the CO₂ factor from your national inventory: the US EPA's equivalencies calculator uses 0.0053 tonnes per therm of natural gas (11.7 lb), and the UK government's 2024 reporting factor for natural gas is 0.1829 kg CO₂e per kWh (gross calorific value). Then weigh the saving against what the windows cost, and against the comfort, condensation and noise reasons that usually decide a window replacement before the fuel bill does.

Adjusting the defaults

Every input is editable and the result updates as you type. The U-value sliders run from the best triple glazing up to single glass, the heating hours from 500 to 5,000 a year, and the temperature difference from near zero to a deep-winter average. The fuel price is per therm on the US side and per kWh on the metric side, and for electric heating the electricity price goes in the same field (per therm is the per-kWh price × 29.3). If the new U-value is not lower than the old one the calculator says so rather than reporting a negative saving.

Using this window energy savings calculator alongside other BuildMetricLab tools

The triple-pane window savings calculator runs the same physics with a boiler efficiency, an installed cost and a payback; the air sealing calculator covers the gaps around the frames, and the solar panel savings calculator sits beside this one in the same category for the generation side of the bill. Every BuildMetricLab tool runs entirely in your browser, nothing you type is sent anywhere, and the formula is shown on the page so you can audit the maths.

Sources & methodology

Heat lost through glazing by conduction is U × A × ΔT; summed over the heating season the reduction from a lower U-value is (U₀ − U₁) × A × ΔT × h ÷ 1,000 kWh, where A is the glazed area, ΔT the average indoor-to-outdoor temperature difference and h the heating hours (ΔT × h ÷ 24 is the heating degree-days, shown in the result). Cost saving = heat × fuel price and CO₂ avoided = heat × emission factor, both on the heat basis; the 90% row divides all three by 0.9, the 0.90 AFUE that the US Department of Energy's FEMP guidance gives as the ENERGY STAR level for residential gas boilers (baseline 0.84, best listed 0.97). Imperial inputs are converted before the calculation at 5.678263 W/m²K per BTU/h·ft²·°F, 5/9 °C per °F of difference, 0.09290304 m² per ft² and 29.3071 kWh per therm. Default U-values follow the US Department of Energy's consumer guide (window U-factors from 0.20 to 1.20) and, on the metric side, the 1.4 W/m²K limit for replacement windows in Approved Document L Table 4.2 (England). Default CO₂ factors are the US EPA's 0.0053 t CO₂ per therm of natural gas (11.7 lb) and the UK government's 2024 reporting factor of 0.1829 kg CO₂e per kWh (gross CV). The model covers conduction through the glass only: frames, air leakage, solar gain and cooling are excluded, and no prices or tariffs are embedded.

Frequently asked questions

Are window energy savings calculator results accurate enough to base a purchase decision on?

They are a planning figure for one heat path, conduction through the glass, and the arithmetic is exact for the inputs; what moves the answer is the inputs. The U-values should be whole-window figures from the labels, and the temperature difference times the heating hours should match your local heating degree-days (shown in the result as a check). The tool leaves out air leakage, solar gain and cooling, so a whole-house saving can differ either way. Get the window quotes and compare the cost with the saving, and with the comfort and condensation reasons, before deciding.

Where do I find the U-value of my existing and new windows?

New windows carry it on the NFRC label in North America (BTU/h·ft²·°F) or the product datasheet and energy rating label in the UK, Europe and Australia (W/m²K); use the whole-window figure, not centre-of-glass. For existing windows use the old label if it survives, or the typical figures the US Department of Energy's consumer guide gives: single clear glass about 1.0, older clear double-pane about 0.48, low-E double-pane 0.25 to 0.30, triple-pane 0.15 to 0.22 (multiply by 5.678 for W/m²K: single glazing about 5.8, 1980s double glazing 2.8, current double glazing 1.2 to 1.4).

Does this tool substitute for a professional energy audit?

No. An audit measures the whole house, including the air leakage that this tool ignores and that often saves more than the glass, and it checks the window U-value against the code that applies where you live (Approved Document L in England, the International Energy Conservation Code and state amendments in the US, the National Construction Code in Australia, provincial codes in Canada). This calculator estimates one heat path from the figures you enter.

Can I change the gas price and CO₂ factor?

Yes. Both are editable: the fuel price is per therm on the US side and per kWh on the metric side (1 therm is 29.3 kWh), and the CO₂ factor is per therm or per kWh of fuel. The defaults are natural gas at the US EPA's 0.0053 tonnes per therm (11.7 lb) and the UK government's 2024 factor of 0.1829 kg CO₂e per kWh. For electric heating enter the electricity price and the grid factor; the cost and CO₂ rows are on the heat basis, and the 90% row shows the fuel a condensing boiler or furnace burns for it.

Spotted something off?

Calculations or display — let us know.

Calculators from other categories that planners often reach for next.