BuildMetricLab

Sustainability & Green Build

Solar Panel Savings Calculator

Estimates annual savings from solar panels by system size

Updated May 13, 2026 · Live

What this tool does

Estimates annual savings from solar panels by system size.

Inputs
W
kWh/kWp/yr
kg/kWh
$/kWh
$/kWh
%
Result

Estimated Annual Saving

$725.63

System Size
4.30 kWp
Orientation and Shading Factor
1.00
Annual Generation
5,805 kWh
Self-use / Export
2,612 / 3,193 kWh
Bill Saving from Self-use
$470.21
Export Income
$255.42
CO₂ Avoided
2,148 kg/yr
Installer
Check the installer holds the certification your area or export scheme requires (MCS in the UK)
Plain Estimate
From BrightScale Labs
Invoice maker
Quote at the door. Signed on the spot.
Estimates and invoices for trades, built while you are still in the room.
Scan to get
Get it onGoogle Play

People also use

Formula Used
E=kp⋅G⋅ηo⋅ηsE = k_p \cdot G \cdot \eta_o \cdot \eta_s
EE
Annual generation (kWh)
kpk_p
System size (kWp) = panel count × wattage / 1000
GG
Generation factor (kWh per kWp per year)
ηo\eta_o
Orientation multiplier
ηs\eta_s
Shading multiplier

How the solar panel savings calculator works

The formulas are generation = kWp × yield per kWp × orientation factor × shading factor and saving = self-used kWh × import price + exported kWh × export rate. With the defaults, 10 panels of 430 W make 4.3 kWp. At 950 kWh per kWp a year on a south-facing, unshaded roof that is 4.3 × 950 = 4,085 kWh. With 45% used in the home, 1,838 kWh is self-used and 2,247 kWh is exported. Self-use is worth 1,838.25 × £0.27 = £496.33 and export 2,246.75 × £0.15 = £337.01, so the saving is £833.34 a year. At 0.207 kg of CO₂ per kWh the system avoids 4,085 × 0.207 = 846 kg of CO₂ a year.

The orientation and shading choices multiply the yield. East or west is 0.83 and north is 0.62; light shading is 0.9 and heavy is 0.7. East or west with light shading is 0.83 × 0.9 = 0.75, so output drops to 3,051 kWh and the saving to about £622.50. These multipliers are planning figures, so use a solar-resource tool for a real value. The currency symbol shown is £, but the maths works in any currency if you enter your own prices.

Typical UK sustainability and green build wastage

For solar, the error that matters is not waste but sensitivity. The biggest swing is the self-use share. At 30% self-use the default system saves 1,225.5 × £0.27 + 2,859.5 × £0.15 = £759.81; at 70% it saves £955.89. The spread comes from the gap between what you pay for grid power and what you are paid to export. If that gap is small, self-use matters little; if it is large, a battery, a diverter or moving daytime loads can pay. Yield is the second swing: a 10% error in the generation factor is a 10% error in the answer.

What this tool does not do

It does not price the system, so it gives no payback. Divide your installed quote by the annual saving: a £6,500 quote against £833.34 is 6,500 ÷ 833.34 = 7.8 years before any change in tariffs or output. It does not model panel degradation, the cost of an inverter replacement, seasonal profiles, a battery, time-of-use tariffs or changing energy prices. It does not check the roof structure, shading in detail or grid capacity. It does not apply any grant, tax or incentive.

On-site considerations for solar panel savings

Solar installation is work at height and live electrical work. In Great Britain see HSE roof work for the duties on roof work; other countries have their own rules. A roof must carry the weight and wind loads of the array, and a structural check may be needed. DC wiring from the panels stays live in daylight, so the installation, isolation and testing must be done by a competent, certified installer. Use a solar-resource tool such as PVGIS (European Commission) or the Global Solar Atlas to replace the default yield with a figure for your site, tilt and direction.

Building Regulations and compliance

In the UK, grid connection of a home system needs notice to or approval from the network operator, and installers work to the national wiring standard, BS 7671. In England, rooftop solar on a house is often permitted development, with limits for listed buildings and some conservation areas, so check with your local planning authority. Under the Smart Export Guarantee regulated by Ofgem, licensed suppliers pay small generators for electricity they export; the rate and conditions, including installer certification such as MCS, differ by supplier, so check before you sign. Elsewhere, export payments and net metering rules vary widely. Scotland, Wales and Northern Ireland have their own building rules.

Before you order

Ask each installer for a written design with the expected annual output in kWh, the roof direction and tilt, the shading assumptions and the inverter. Compare the quoted output with this tool; a large gap means a different yield or shading assumption, and it is worth asking why. Check the product and performance warranties, which commonly run for many years, and what happens if the installer stops trading. Compare at least three itemised quotes on the same basis. Use the UK government conversion factors for the grid carbon figure if you want the current UK value.

Adjusting the defaults

Every input can be changed. If you have a quote, replace the generation factor with the installer's annual output divided by the system kWp. If you know your daytime use, set the self-use share to match it; a household at home all day may reach 60–70%, and an empty house in the day often sits at 30% or below. Set the export rate to 0 if you are not paid for export. The default prices of £0.27 and £0.15 are placeholders, not market figures, and they change.

Using this solar panel savings calculator alongside other BuildMetricLab tools

Size the array first with the solar array sizing calculator, then check the inverter with the inverter sizing calculator and a battery with the battery bank calculator. Everything runs in your browser, nothing is sent anywhere, and the formula is shown so you can check the maths. Conversions follow NIST SP 811.

Sources & methodology

Generation = kWp × yield per kWp × orientation factor × shading factor, where kWp = panels × panel W ÷ 1,000. Orientation factors are 1.00 (south or equator-facing), 0.83 (east or west) and 0.62 (north); shading factors are 1.00 (none), 0.90 (light) and 0.70 (heavy). These are planning multipliers, not measurements. Self-used kWh = generation × self-use share; exported kWh = the rest. Saving = self-used kWh × import price + exported kWh × export rate. CO₂ avoided = generation × grid intensity. Panel count must be a whole number of 1 or more; the self-use share must be 0–100%; prices and grid intensity cannot be negative; a blank export rate counts as zero and other blanks are refused. No tariffs, grants or yield database are embedded, and the tool does not include panel degradation, a battery or system cost.

Frequently asked questions

Are solar panel savings calculator results accurate enough to decide on an installation?

They are a first estimate. The result is only as good as the yield, the self-use share and the prices you enter, and the orientation and shading factors are planning multipliers. Use it to compare options, then ask installers for a written design with expected annual output and compare it with this tool.

What generation factor and self-use share should I use?

The generation factor is the annual kWh per kWp on an unshaded, equator-facing roof. The default 950 is a typical UK figure; look up your own site in PVGIS or the Global Solar Atlas. Self-use depends on how much you use in the daytime, and homes with a battery or high daytime use have a higher share than the 45% default.

Does this replace professional advice?

No. This tool is a planning estimator. Solar installation involves work at height, live electrical work, structural loads and grid-connection rules. For works that affect structure, Building Regulations, the electrical installation or the grid connection, consult a suitably qualified professional.

Can I change the unit prices?

Yes. The import price and export rate are editable, and you can leave the export rate blank if you are not paid for exported power. Enter the figures from your own bill and tariff to get a result that matches your home. The currency symbol shown is £, but the arithmetic works in any currency.

Spotted something off?

Calculations or display — let us know.

Calculators from other categories that planners often reach for next.