Perforated pipe for a yard or land drainage system from area, spacing and main

Updated October 1, 2026 · Live

What this tool does

Works out the perforated pipe a yard, lawn or field drainage system needs: laterals from the area and spacing, plus the collector main, with the cost at your pipe price.

Area divided by lateral spacing gives the laterals; the main is added; the total is priced per metre or foot.

Inputs
ft²
ft
ft
in
$
Result

Perforated Drain Pipe Required

334 ft

Area to Drain
4,300.0 ft²
Lateral Spacing
16.0 ft
Lateral Pipe (area ÷ spacing)
268.8 ft
Collector Main (square plot assumed)
65.6 ft
Laterals (parallel layout, approx.)
4
Pipe Diameter
4 in perforated
Estimated Cost
$401.19
Spacing Guidance
Yards and gardens 10 to 20 ft; fields 25 to 150 ft by soil, closest on clay
Price it on PlainEstimate

Opens these materials as a new estimate on PlainEstimate, our free estimate and invoice app.

Plain Estimate
From BrightScale Labs
Invoice maker
Quote at the door. Signed on the spot.
Estimates and invoices for trades, built while you are still in the room.
Scan to get
Get it onGoogle Play

People also use

Formula Used
Lt=As+ML_t = \frac{A}{s} + M
LtL_t
Total pipe (ft)
AA
Area to drain (ft²)
ss
Lateral spacing (ft)
MM
Collector main (ft); √A when not entered

How the drainage calculator works

A piped drainage system for a lawn, paddock or field is a set of parallel perforated pipes, the laterals, feeding one collector main that runs to an outlet. The calculator works out how much pipe that takes. Laterals spaced a fixed distance apart across an area always add up to the area divided by the spacing, whatever shape the plot is. 400 m² at 5 m centres is 80 m of lateral pipe whether that is eight 10 m runs or four 20 m ones. The main is added on top. If you know how long it will be, enter it; if not, the calculator assumes a square plot and takes one side, the square root of the area.

With the metric defaults, 400 m² at 5 m spacing: 400 ÷ 5 = 80 m of laterals and √400 = 20 m of main, 100 m of pipe in all. That is £180 at £1.80 a metre, with about four laterals (20 ÷ 5). With US units, 4,300 ft² at 16 ft spacing: 4,300 ÷ 16 = 268.8 ft of laterals, √4,300 = 65.6 ft of main, 334 ft in all, about $401 at $1.20 a foot. Pipe comes in coils and lengths, so round the total up to what the supplier sells. In the UK that is 25 m, 50 m and 100 m coils of 80 mm land drain; in the US, 100 ft and 250 ft rolls of 3 in or 4 in corrugated pipe.

Why the main length matters

The square assumption is a stand-in, not the typical case. A 40 m × 10 m strip of garden along a boundary has the same 400 m² and the same 80 m of laterals at 5 m. But the main runs the 40 m length, so the total is 120 m, not 100 m. Enter the main length and the calculator uses it, and the lateral count follows from it: 40 ÷ 5 is eight laterals, each 10 m. The lateral count on the card assumes laterals running straight across from one side of the main. A herringbone, with laterals meeting a central main at 45° from both sides, uses about the same total of pipe but has roughly 1.4 times as many laterals, each shorter. Read the count as a guide to the layout, not a shopping list of junctions.

Choosing the spacing

Spacing depends on the soil and on how fast the ground has to drain. For gardens, the RHS guidance on installing drainage is perforated pipe laid 40 to 60 cm (16 to 24 in) deep and 3 to 6 m (10 to 20 ft) apart. It describes a herringbone layout on a fall of 1 in 40 to the outlet. Fields are drained to a different scale. Purdue University's Drainage and Wet Soil Management guide (AY-300) has drain lines at least 30 to 36 in (76 to 91 cm) deep on a grade of 0.1% to 0.5%. Its parallel spacings run from 25 to 50 ft on heavy lake-plain clays to 75 to 150 ft on coarse soils, with 60 to 120 ft the common middle; wider still is reserved for organic muck. It is an Indiana guide from 2001, but the rule it rests on, closer drains in slower soil, holds everywhere. The default of 5 m (16 ft) is a garden figure; a field on loam would use something nearer 20 m (66 ft) and need under a third of the pipe. On a square hectare with a 100 m main, that is 600 m of pipe at 20 m spacing against 2,100 m at 5 m.

Pipe size and the outlet

The diameter you enter goes on the order line; the length is the same whatever size you pick. In the UK, laterals in gardens and small fields are usually 80 mm perforated land drain, with the main stepped up to 100 mm where it collects more than a few laterals. In North America, 4 in corrugated pipe is the stocked size for a yard job and does both. Australians call the same product ag pipe, Canadians weeping tile. The RHS lists ditches, streams and soakaways as outlets and notes that local byelaws usually prohibit sending garden drainage to sewers or storm drains. In the US, discharging to a storm drain, a ditch or a neighbour's land is governed by local stormwater rules, and a dry well needs a percolation test to size. The fall to that outlet, not the pipe quantity, is what decides whether the system works, so find the outlet level first.

What the count does not include

Gravel or shingle (washed stone, in the US) to bed and surround the pipe, the geotextile sock or membrane, the junctions and end caps, and the excavated soil to cart away are separate. Allow extra pipe for the connections and for trimming at the junctions; the coil rounding often covers it. A single run is not laterals at all, whether it circles a basement as weeping tile, sits behind a retaining wall or cuts across a slope to intercept water. Enter its length in the French drain calculator, which also does the trench and stone.

Using this with other BuildMetricLab tools

Run this count first, then the French drain calculator for the trench and stone along the main. The gravel calculator turns that stone into tonnes for delivery, and the soil compaction calculator sizes the spoil once it is out of the ground. All BuildMetricLab tools run in your browser with no sign-up, and the formula is on the page so the maths can be checked.

Sources & methodology

Lateral pipe = area ÷ lateral spacing. Collector main = the length entered, or √area if none (a square plot). Total pipe = laterals + main. Laterals (approx.) = main ÷ spacing, rounded. Cost = total pipe × price per unit length. The pipe diameter is carried for the order line. Gravel, geotextile, fittings and spoil are not counted.

Frequently asked questions

Are yard drainage calculator results accurate enough to order materials?

For the pipe, yes, once you have entered the real spacing and, if the plot is not square, the length of the main. Buy whole coils or rolls; the count does not include gravel, geotextile, fittings or spoil removal.

Does this calculator include a wastage allowance for pipe or fittings?

No. It gives the geometric length: laterals as area divided by spacing, plus the main. Add 5% to 10% for trimming at the junctions and the connections themselves, or let the rounding up to whole coils cover it, which on a small system it usually does.

Is this a substitute for a licensed contractor or engineer?

No. It counts pipe. The depth, fall and outlet decide whether the system drains, and most places restrict where drainage water may go. For a field, or anywhere the water table or a neighbour's land is involved, a drainage contractor or engineer should design it.

Can I change the unit prices?

Yes. The price per foot or metre of pipe is an input; enter the price for the diameter you are buying, divided by the coil length if it is sold by the coil, and the cost is recalculated.

Spotted something off?