Kitchen
Range Hood / Vent Hood Sizing Calculator
Range hood airflow in CFM from kitchen size and cooking style
Updated May 13, 2026 · Live
What this tool does
Estimates the range hood airflow in CFM from the kitchen's volume and your cooking style, using the air-changes-per-hour method.
Estimates the range hood airflow in CFM from the kitchen's volume and a cooking-style air-change rate.
People also use
Formula Used
Formula Used
How the range hood / vent hood sizing calculator works
A cooker hood has to move enough air to carry cooking steam, heat and fumes out of the kitchen. This calculator uses the air-changes-per-hour method: it works out the kitchen's volume, multiplies by a number of air changes an hour that depends on how you cook, and gives the airflow. The formula is Q = L × W × h × a. The page works in feet, with the result in CFM (cubic feet a minute) and m³/h, and converts internally, so the metric and US-unit versions of the same kitchen agree.
Example with the defaults on this page: a kitchen 13 ft long, 10 ft wide and 8 ft high has a volume of 13 × 10 × 8 = 1,040 ft³, which is 29.4 m³. At 15 air changes an hour (mixed cooking) that is 1,040 × 15 = 15,600 ft³ of air an hour, and dividing by 60 gives 260 CFM. In metric, that is 442 m³/h or 123 l/s. Light cooking at 10 ACH gives 173 CFM and heavy cooking at 20 ACH gives 347 CFM.
Range output gives a second view. A rule of thumb used by hood makers is about 1 CFM for every 100 BTU/h of burner output, so a range with four 15,000 BTU/h burners (60,000 BTU/h) suggests about 600 CFM, more than twice the room figure. A large 20 × 15 × 9 ft kitchen at heavy cooking needs 900 CFM by the volume method, above the 400 CFM line at which many US codes ask for make-up air.
Typical US kitchen wastage
There is no wastage on an airflow figure, so the question is how closely the number reflects what a hood delivers. The air-change rates of 10, 15 and 20 an hour are planning values and not a published standard, so treat the result as a first estimate. A hood's rated airflow is measured with no duct, and real ducts have bends, length and a wall cap, which add resistance and reduce the airflow. A long run with several bends can cut it noticeably, so choose a hood with some margin and check its airflow at your duct's resistance.
What this tool does not do
It does not size the hood to the range or hob. The width and height of the hood, and how much of the cooking area it captures, matter as much as the airflow, and a hood should be at least as wide as the cooker. It does not account for the burner output, the duct run, make-up air or noise. It does not choose between a ducted and a recirculating hood, and a recirculating hood removes grease and some odour but not steam, heat or combustion products. It is a first airflow estimate and not a design.
On-site considerations for range hood / vent hood sizing
Capture matters more than a big number. A hood that is wider than the cooker, mounted at the height the maker states, and fitted with a short, straight, smooth duct to the outside works better than a more powerful hood with a long run. Use the duct size the hood's maker specifies, and keep it as short and straight as you can, with few bends. Check the model's airflow at the resistance of your duct, and its noise rating, which is given in sones in the US and in decibels elsewhere. A hood that is too loud will not be used.
A hood that moves a lot of air pulls the same air back in from somewhere else. In a tight house a big hood can pull flue gases back down a chimney or from a gas appliance, which is a safety issue. That is why many US codes require make-up air above 400 CFM, and why a tight house may need a way for air to enter. Ask your installer and building department.
Codes and compliance
In the United States the International Residential Code requires a hood to exhaust to the outside, and many codes require make-up air for a hood that moves more than 400 CFM, with the details depending on the code edition your area adopts. ENERGY STAR rates ventilation fans for airflow at a stated static pressure, for sound in sones and for efficiency. Gas cooking releases combustion products as well as steam, and the WHO notes that improved ventilation reduces household air pollution from cooking. A hood fitted for a new kitchen is building work in many places, so check whether a permit or notice is needed. Other countries have their own rules, so follow the ones where you live.
Before you order
Measure the range or hob width and choose a hood at least that wide. Decide whether the hood will be ducted to the outside, which is the better choice, or recirculating. Check the model's airflow at the static pressure of your duct, its noise rating and its efficiency. Compare the airflow with the volume figure and, for a gas range, the output figure, and choose the larger if the room is big. Ask whether your kitchen needs make-up air, and plan the duct route, the wall cap and the power supply before you buy.
Adjusting the defaults
Every input is editable. The length, width and ceiling height must be above zero, and a blank or zero field is refused instead of silently using a default. Choose the cooking style that fits how you cook, because it changes the result by a factor of two between light and heavy. For an open-plan room, enter the space the hood should serve, and compare the result with the range-output figure.
Using this range hood / vent hood sizing calculator alongside other BuildMetricLab tools
Pair this estimate with the kitchen backsplash, cabinet and countertop calculators to plan the whole kitchen. All BuildMetricLab tools run in your browser. Nothing you type is sent anywhere, and every formula is shown on the page so you can audit the maths.
Sources & methodology
Airflow = kitchen volume × air changes per hour (ACH). Volume is length × width × ceiling height. The ACH rate is 10 for light cooking, 15 for mixed cooking and 20 for heavy cooking. In US units, CFM = volume in ft³ × ACH ÷ 60, and the page also shows m³/h (1 CFM = 1.699 m³/h). The ACH rates are planning values and not a published standard. The reference row quotes the England Part F minimums for comparison. The length, width and height must be above zero. The make-up air note appears when the result passes 400 CFM, a threshold many US codes use, but the requirement and its numbering depend on the code edition your area has adopted. The tool does not model the duct, the hood's capture area or the burner output, and a hood's rated airflow is for no duct resistance.
- ENERGY STAR — Ventilation fans: airflow, sound (sones) and efficacy ratings (US)
- Home Ventilating Institute (HVI) — residential ventilation and kitchen exhaust standards (US)
- WHO — Household air pollution and health: cooking fumes and ventilation (international)
- NIST — Special Publication 811, Guide for the Use of the International System of Units (CFM, m³/h and l/s)
Frequently asked questions
Are range hood / vent hood sizing calculator results accurate enough to order materials?
They are a planning figure, not a specification. The tool gives a starting airflow in CFM from the kitchen's volume and your cooking style. A hood's real performance depends on the duct length, bends and outlet, which reduce the airflow below the rated figure, so check the model's airflow at the static pressure of your duct run and size for the range as well as the room.
Why do I need to pick a cooking style?
The cooking style sets the air-change rate in the volume method: 10 air changes an hour for light cooking such as baking and boiling, 15 for mixed everyday cooking and 20 for heavy frying or grilling. Heavier cooking puts more heat, smoke and grease into the air, so it calls for more airflow. These rates are planning figures and not a published standard.
Does this replace professional advice?
No. It gives a first airflow figure only. It does not check the range, the hood's capture area, the duct or the make-up air. A hood over a gas range involves combustion and an exhaust to the outside, so use a qualified installer and follow your local code and the manufacturer's instructions.
What if my kitchen is an open-plan or combined space?
Use the volume of the space the hood should serve. For an open-plan room with no partition, that may be the whole room, which gives a very large figure. In practice a hood is chosen mainly for the range it sits over: a common rule of thumb is about 1 CFM per 100 BTU/h of burner output, so a 60,000 BTU/h range suggests about 600 CFM, and the hood should be at least as wide as the range. Compare both figures and ask the manufacturer.
Spotted something off?
Calculations or display — let us know.
Related tools