Vapour Barrier Calculator
Calculates rolls of 6-mil (0.15 mm) poly vapour barrier for walls and ceilings
Updated October 13, 2026 · Live
What this tool does
Calculates the number of rolls of 6-mil (0.15 mm) polyethylene vapour barrier needed for a wall or ceiling, from the area, the coverage of one roll and an allowance for laps and offcuts.
Estimates the rolls of 6-mil (0.15 mm) poly needed to cover a wall or ceiling, with an allowance for laps and penetrations, the spare sheet in the last roll and the cost at your supplier's roll price.
People also use
Formula Used
Formula Used
How the vapour barrier calculator works
Take the wall or ceiling area, add a percentage for the laps where one sheet runs over the next and for the offcuts around boxes, pipes and windows, divide by the area one roll covers, and round up to whole rolls. That is the whole calculation: rolls = ⌈area × (1 + allowance) ÷ roll coverage⌉. With the defaults, 40 m² (430 ft²) of wall plus 10% is 44 m², and a 50 m² roll covers it with 6 m² to spare. On the US side the same wall is 430 ft² plus 10%, 473 ft², and a 1,000 ft² roll leaves 527 ft² over, enough to do the ceiling of the same room. The rounding matters more than the percentage: 120 m² at 15% is 138 m², which needs three 50 m² rolls, and taking the allowance down to 10% (132 m²) still needs three.
The sheet itself is 6-mil (0.15 mm) polyethylene, the thickness Natural Resources Canada names in its Keeping the Heat In guide as the one commonly installed, chosen because thinner film does not survive a building site. Rolls are sold by area rather than by length, and the common Canadian stock sizes from one film maker's list are 500 ft² (102 in × 59 ft, about 46 m²), 1,000 ft² (10 × 100 ft, 93 m²) and 2,000 ft² (20 × 100 ft, 186 m²), all made to CAN/CGSB-51.34. Put the size your supplier actually stocks into the roll coverage field; the metric default of 50 m² is close to the 500 ft² roll.
Where the vapour barrier goes
On the warm side of the insulation, which in a heating climate means the room side, directly behind the drywall. Warm indoor air carries water vapour, and if that vapour diffuses into the wall it reaches the cold sheathing and condenses there. A sheet with low permeance on the warm face stops it getting in. Canada's National Building Code deals with this in Section 9.25: Sentence 9.25.4.2.(1) caps the vapour barrier's permeance at 60 ng/(Pa·s·m²) measured by the ASTM E96 dry-cup method, about 1.05 US perms, and 9.25.4.3 requires the vapour barrier to protect the warm side of the assembly. A 6-mil sheet sits far below that limit. The US code describes the same sheet as a Class I vapour retarder, 0.1 US perm or less, and in the UK and Ireland it is a vapour control layer under BS 5250. The job is the same in all three; only the name and the test units change.
The warm side is not always the inside. Building Science Corporation's digest on vapour barriers puts an interior polyethylene sheet in the classic very cold climate wall and warns against vapour barriers on both faces of an assembly, because a wall that cannot dry in either direction stores every leak. In a hot, humid climate with air conditioning the warm side is outdoors for most of the year, and a poly sheet behind the drywall traps moisture against the cool interior. If your summers are long and sticky rather than your winters, check the assembly with someone who knows your local code before buying any poly at all.
Poly grades and air-barrier details
Six-mil polyethylene doubles as the air barrier when its laps and edges are sealed, and NRCan's guidance on how to do that is specific: overlap every seam over a solid backing such as a stud or joist, run a bead of non-hardening acoustical sealant between the two sheets over that support, and staple through the sheet and the bead rather than anywhere else. The code's own minimum for a flexible sheet air barrier (9.25.3.3) is that joints are sealed, or lapped at least 100 mm (4 in) and clamped between framing and a rigid panel. Electrical boxes get an air-barrier box or a poly hat sealed back to the main sheet, with the cable entry caulked. House wrap on the outside is an air barrier only and does not do the vapour barrier's job. Some assemblies use a polyamide "smart" membrane instead of poly, which resists vapour in winter and opens up in warm weather so the wall can dry inward; NRCan advises against it in pools, spas and bathrooms where the humidity is permanent. Closed-cell spray foam at about 50 mm (2 in) and some rigid foams also qualify as the vapour barrier, in which case you need no poly and this calculator does not apply.
What this tool does not do
It counts sheet. It does not choose the membrane for your wall, decide whether poly or a smart membrane is right for your climate, design the continuity of the air barrier at the rim joist and window openings, or check where the dew point falls inside the insulation. Those depend on the build-up, the climate zone and the indoor humidity, and NRCan's one-third rule (no more than a third of the wall's insulating value on the warm side of the barrier, a quarter or less in very cold climates or humid buildings) is the kind of check it leaves to you. It also does not price the acoustical sealant, sheathing tape or box seals, which on a small job can cost more than the poly.
Adjusting the defaults
Every input is editable and the result updates as you type. The area is the wall or ceiling face you will cover, measured on the inside; do not deduct windows and doors, because the sheet runs across them and is cut out afterwards, and the offcut is waste. The lap and waste allowance covers both the overlaps at the studs and those cut-outs. Ten percent suits a plain wall worked with wide sheets; go to 15% or more on a room with several windows, a sloped ceiling, or a first attempt. The roll coverage and price come from your supplier's listing. The cost line multiplies whole rolls by the price, so it is a shelf price in the page currency and not an installed cost.
On-site considerations
Lap sheets over a stud or plate, never in the middle of a bay, and seal the lap so the poly is continuous as both a vapour and an air barrier. Use the widest sheet the wall allows: a 20 ft roll run horizontally does a 2.4 m (8 ft) wall in one pass with a single lap at the plates, while a narrow roll adds a seam at every joint, and every seam is a place for the seal to fail. Detail the awkward spots first, electrical boxes, plumbing penetrations, the rim joist and the window frames, because those gaps leak the most air. If the sheet will see sunlight for more than a few days during a renovation, buy the UV-stabilised grade. And do not add a second vapour barrier over an existing one, or over a wall that already has one on the other face.
Using this alongside other BuildMetricLab tools
Pair this with the attic insulation calculator for the ceiling you are sealing beneath, the attic baffle calculator for the eaves ventilation above it, and the air sealing calculator for the sealant and gaskets at the joints. Every BuildMetricLab tool runs in your browser, nothing you type is sent anywhere, and the formula is shown on the page so you can audit the maths.
Sources & methodology
Rolls = ⌈A × (1 + o) ÷ c⌉, where A is the wall or ceiling area, o the lap and waste allowance as a decimal and c the area one roll covers; the spare sheet is rolls × c minus A × (1 + o), and the cost is rolls × price per roll. Imperial areas are converted at 0.09290304 m² per ft² before the calculation and shown back in ft². The sheet assumed is 6-mil (0.15 mm) polyethylene, the thickness Natural Resources Canada's Keeping the Heat In guide names as the one commonly installed as a vapour barrier, conforming to CAN/CGSB-51.34; the stock roll sizes quoted (500, 1,000, 1,500 and 2,000 ft²) are from Mercury Plastics' Construction Poly product list. Placement on the warm side of the insulation, lapping over a stud or joist with a bead of acoustical sealant, and sealing of boxes and penetrations follow the NRCan guide; the warning against vapour barriers on both faces of an assembly follows Building Science Corporation BSD-106. Sentence 9.25.4.2.(1) of the National Building Code of Canada, as published in the British Columbia Building Code 2018, limits vapour barrier permeance to 60 ng/(Pa·s·m²) by the ASTM E96 dry-cup method (about 1.05 US perms at 57.2 ng/(Pa·s·m²) per perm), 9.25.4.3.(1) requires products installed as the vapour barrier to protect the warm side of wall, ceiling and floor assemblies, and 9.25.3.3 requires flexible sheet air barrier joints to be sealed or lapped at least 100 mm and clamped. No prices or rates are embedded; the roll price is your input.
- Natural Resources Canada, Keeping the Heat In, Section 3: Materials (3.3 air barrier materials, 3.4 vapour barrier materials: 0.15 mm (6 mil) polyethylene to the CGSB standard, warm-side placement, one-third rule, supported and sealed seams)
- Natural Resources Canada, Keeping the Heat In, Section 4: Comprehensive air leakage control (overlap seams over a stud, acoustical sealant bead in the lap, staple through the bead, seal boxes and penetrations)
- Lstiburek, J., BSD-106: Understanding Vapor Barriers, Building Science Corporation (Class I vapour retarder 0.1 perm or less, polyethylene is Class I, interior Class I in very cold climates, avoid double vapour barriers)
- Mercury Plastics, Construction Poly product list (6-mil CGSB vapour barrier rolls of 500, 1,000, 1,500 and 2,000 ft²; CAN/CGSB-51.34-M86)
- National Research Council Canada, Codes Canada: National Building Code of Canada 2020 (Part 9, Section 9.25 heat transfer, air leakage and condensation control)
- British Columbia Building Code 2018, Division B, Section 9.25 Heat Transfer, Air Leakage and Condensation Control (NBC text: 9.25.4.2.(1) permeance not greater than 60 ng/(Pa·s·m²) by ASTM E96 dry cup; 9.25.4.3 vapour barrier protects the warm side; 9.25.3.3 sheet joints sealed or lapped 100 mm and clamped)
Frequently asked questions
Are vapour barrier calculator results accurate enough to order materials?
They are a good starting estimate: the roll count is whole rolls of the coverage you enter, with your lap and waste allowance on top, so for a plain wall it is usually exact. Check the roll size against the supplier's listing before ordering, since 6-mil poly comes in 500, 1,000, 1,500 and 2,000 ft² rolls (about 46 to 186 m²) and the count changes with the size. Sealant, tape and box seals are not included.
What wastage percentage should I use?
The default 10% covers the laps over studs and joists plus the offcuts around boxes, pipes and window openings on a plain wall worked with wide sheets. Use 15% or more for a room with several openings, a sloped ceiling or narrow rolls that add a seam at every joint, and for a first attempt. The area you enter should be the full wall face without deducting windows and doors, because the sheet is run across them and cut out afterwards.
Does this replace professional advice?
No. It counts sheet; it does not decide whether a polyethylene vapour barrier is right for your wall and climate, where it goes in the assembly, or how the air barrier stays continuous. Those are governed by your building code (Section 9.25 of the National Building Code in Canada, the vapour retarder provisions of the residential code in the US, BS 5250 in the UK), and in a hot, humid climate an interior poly sheet can trap moisture instead of keeping it out. Confirm the assembly with a building professional who knows the local code.
Can I change the unit prices?
Yes. The price per roll is editable and the cost line is simply whole rolls multiplied by that price, in the page currency. Put in your supplier's quote for the roll size you entered and the total matches your project; it does not include sealant, tape or labour.
Spotted something off?
Calculations or display — let us know.