Conversions & Units
kW to BTU Calculator
Converts kilowatts to BTU/hr, horsepower and tons of refrigeration with the exact factor
Updated October 14, 2026 · Live
What this tool does
Converts a heat output or power figure in kilowatts to BTU per hour, with horsepower, watts and tons of refrigeration alongside. The factor 1 kW = 3,412.142 BTU/hr is exact.
kW to BTU: enter a power or heat-output figure in kilowatts and read the exact equivalent in BTU per hour, horsepower, watts and tons of refrigeration.
People also use
Formula Used
How the kW to BTU/hr conversion works
A kilowatt and a BTU per hour both measure power, the rate at which energy moves. Type a figure in kilowatts and the calculator multiplies it by 3,412.142 to give BTU per hour, rounded to the nearest whole unit. The default of 3 kW, roughly a small split air conditioner or a large electric heater, comes out at 10,236 BTU/hr. Three more lines follow: mechanical horsepower (kW × 1.34102), watts (kW × 1,000) and tons of refrigeration (BTU/hr ÷ 12,000), plus the factor in both directions so you can run a BTU/hr figure back to kilowatts without a second tool.
Nothing here is estimated. The factor is fixed by the definitions of the two units, and the only uncertainty in any result is the kilowatt figure you typed.
The exact conversion factor
The BTU used here is the International Table BTU, defined as exactly 1,055.05585262 joules and listed as such in Appendix B.9 of NIST Special Publication 811. One kilowatt is 1,000 joules every second, which is 3,600,000 joules an hour. Divide that by the joule value of one BTU and you get 3,600,000 ÷ 1,055.05585262 = 3,412.1416 BTU/hr per kW. The calculator carries the full value and the copy quotes 3,412.142, the figure most engineering references print; the two differ by four ten-thousandths of a BTU, about one part in ten million.
The same number also converts energy: one kilowatt hour is 3,412.142 BTU. That is why the figure turns up on electricity bills and in boiler efficiency tables as well as on equipment nameplates.
What kilowatts and BTU/hr measure
Both are the same physical quantity in different systems. The kilowatt is the SI unit, used on boiler, heat pump and radiator data sheets across Europe, the United Kingdom, Australia and most of Asia. BTU/hr belongs to the US customary system and remains the everyday unit for heating and cooling capacity in the United States and Canada. Because much of the world's air-conditioning industry builds to North American conventions, a BTU/hr rating often appears on the box and the remote control of a unit sold in a metric country, while the installer's heat-loss calculation sits in kilowatts.
For heating, a 3.5 kW electric radiator puts out 3,500 W, which is 3.5 × 3,412.142 = 11,942 BTU/hr. A domestic gas boiler rated at 18 kW delivers about 61,419 BTU/hr. Some manufacturers in Asia and southern Europe also quote cooling capacity in kilocalories per hour; 1 kW is 859.85 kcal/h, so a 2,000 kcal/h unit is about 2.3 kW.
Worked examples
- 1 kW: 1 × 3,412.142 = 3,412 BTU/hr (1.341 hp, 1,000 W)
- 2.5 kW: 2.5 × 3,412.142 = 8,530 BTU/hr (3.353 hp, 2,500 W)
- 3.5 kW: 3.5 × 3,412.142 = 11,942 BTU/hr (4.694 hp, 3,500 W), near enough the 12,000 BTU/hr of a nominal one-ton unit
- 5 kW: 5 × 3,412.142 = 17,061 BTU/hr (6.705 hp, 5,000 W)
- 10 kW: 10 × 3,412.142 = 34,121 BTU/hr (13.410 hp, 10,000 W)
Going the other way, divide by the same factor: 9,000 BTU/hr is 2.638 kW, 12,000 BTU/hr is 3.517 kW and 18,000 BTU/hr is 5.275 kW, the three most common small split-system sizes.
Where this conversion appears in construction and HVAC practice
The usual trigger is matching a room load to a product. A heat-gain calculation gives a cooling load in kilowatts, and the units on the shelf are labelled 9,000, 12,000 or 18,000 BTU. A 3.5 kW load lands on the 12,000 BTU unit, which North American catalogues call a one-ton unit. The same thing happens in reverse when a client sends a radiant panel or process heater specification in BTU/hr and the electrical supply, the heat pump schedule or a certification document such as the UK's Microgeneration Certification Scheme paperwork wants kilowatts.
Imported plant is the other source. Control panels, data loggers, chillers and fan coil catalogues from North American or East Asian makers often record capacity in BTU/hr, and a commercial chiller may be sized in tons rather than either unit. Converting once, at the design stage, keeps every figure on a schedule in the same unit, which is where most sizing mistakes are caught.
Horsepower, the third output
The horsepower line uses mechanical horsepower, defined as 550 foot-pounds per second, which is 745.69987 W. One kilowatt is therefore 1,000 ÷ 745.69987 = 1.34102 hp. Horsepower still appears on pump, compressor and motor plates, particularly from North American manufacturers and on older documents elsewhere, where it plays the part the kilowatt rating plays on a European data sheet. Note that this is not the metric horsepower (735.5 W) used on some European engines, nor the boiler horsepower (9,809.5 W) used for steam plant; both would give a different figure.
The tonne of refrigeration relationship
Commercial cooling capacity is often quoted in tons of refrigeration. One ton is the heat absorbed by melting one short ton (2,000 lb) of ice over 24 hours, fixed at 12,000 BTU/hr, which is 3,516.85 W or 3.517 kW. The calculator's tons line divides the BTU/hr result by 12,000, so a 24,000 BTU/hr unit shows as 2.000 TR and converts to 7.034 kW, and a 36,000 BTU/hr unit as 3 TR or 10.55 kW. The nominal sizes on residential equipment are rounded labels rather than tested capacities, so a unit sold as "12,000 BTU" can test a little above or below that figure at rating conditions. Read the capacity on the data sheet, not the model name.
Precision of the results
BTU/hr is shown to the nearest whole number because no nameplate kilowatt figure is better than one or two percent, and the last digit of a five-figure BTU/hr value is well inside that. Horsepower and tons are shown to three decimal places so they can be set against plate ratings directly. The full factor is carried internally, so a value you copy from the result and divide back will return the kilowatts you entered to within rounding. For a calculation that needs more digits, carry 3,412.1416 (3,600,000 ÷ 1,055.05585262) rather than the rounded 3,412.142.
Using this alongside other BuildMetricLab tools
The Celsius to Fahrenheit calculator covers the temperature conversion that usually travels with HVAC paperwork, and the litres to gallons and metres to feet converters handle the other units on an imported specification. The room volume calculator gives the volume a heat-loss calculation starts from, and the pipe insulation calculator covers the distribution side of a heating design. Every BuildMetricLab tool runs in your browser, with no sign-up and no data sent anywhere, and the formula is shown on the page so the maths can be audited.
Sources & methodology
Multiplies the kilowatt figure by 3,600,000 ÷ 1,055.05585262 = 3,412.1416 to give BTU per hour, using the International Table BTU of exactly 1,055.05585262 J (NIST SP 811 Appendix B.9). Horsepower is kW × 1,000 ÷ 745.69987 (mechanical horsepower, 550 ft·lbf/s). Watts are kW × 1,000. Tons of refrigeration are BTU/hr ÷ 12,000 (one ton = 3,516.85 W). The reverse factor, 1,000 BTU/hr = 0.2931 kW, is printed with the result. Inputs must be a number of zero or more; the full factors are carried and only the display is rounded.
- NIST Special Publication 811, Appendix B.9: Factors for units listed by kind of quantity (BTU, horsepower, ton of refrigeration)
- NIST Special Publication 811: Guide for the Use of the International System of Units (SI)
- BIPM: The International System of Units (SI), base and derived units
- BIPM: SI Brochure, 9th edition
Frequently asked questions
Is 1 kW exactly 3,412 BTU/hr?
3,412 is the rounded figure. The exact value is 3,600,000 ÷ 1,055.05585262 = 3,412.1416 BTU/hr per kW, from the definition of the International Table BTU as 1,055.05585262 joules, and most references print it as 3,412.142. It is a defined relationship rather than a measurement, so the only uncertainty in a result comes from the kilowatt figure entered.
Why are air-conditioning units rated in BTU/hr rather than kW?
Much of the air-conditioning industry, in North America and across the East Asian factories that supply the rest of the world, standardised on BTU/hr, so the rating travels with the product even into countries that work in kilowatts. A 12,000 BTU/hr unit is about 3.5 kW of cooling or heating capacity, and the 9,000 and 18,000 BTU/hr sizes are roughly 2.6 kW and 5.3 kW.
How do I convert BTU/hr back to kW?
Divide the BTU/hr figure by 3,412.142, or multiply it by 0.0002931. For example, 12,000 BTU/hr ÷ 3,412.142 = 3.517 kW, which is one ton of refrigeration, the standard unit of capacity in commercial cooling. The calculator prints the factor both ways under the result.
What is a tonne of refrigeration in kW and BTU/hr?
One ton of refrigeration (1 TR) is 12,000 BTU/hr, which is 3,516.85 W or 3.517 kW. It is the rate of heat absorption needed to melt one short ton (2,000 lb) of ice over 24 hours. Commercial chiller capacities are often specified in TR, and the calculator's tons line divides the BTU/hr result by 12,000 so it maps straight onto that scale.
Does this tool replace professional heating or HVAC advice?
The unit conversion is exact and needs no checking. Whether a given kW or BTU/hr figure is the right capacity for a space depends on a heat-loss or heat-gain calculation, the building fabric, occupancy, climate and system design, all of which belong with a qualified heating or HVAC engineer in your country.
Spotted something off?
Calculations or display — let us know.
Related tools