BuildMetricLab

Air Conditioning

Multi-Room AC Sizing Calculator

Total cooling load in BTU/h, kW and tons across up to four rooms

Updated July 12, 2026 · Live

What this tool does

Adds up the cooling load across up to four rooms from their floor areas and a load rate, and suggests whether a single split or a multi-split system suits.

Enter the floor area of up to four rooms and a load rate; the calculator returns the total cooling load in BTU/h, kW and tons.

Inputs
ft²
ft²
ft²
ft²
BTU/h per ft²
Result

Total Cooling Load

17,675 BTU/h

In Kilowatts and Tons
5.18 kW (1.47 tons)
Rooms
3 zones
Largest Zone
7,525 BTU/h (2.21 kW)
Configuration
A multi-split (one outdoor unit, several heads) usually suits this

Diagram

2.2kW1.6kW1.3kWTotal 5.2 kWR1R2R3
Plain Estimate
From BrightScale Labs
Invoice maker
Quote at the door. Signed on the spot.
Estimates and invoices for trades, built while you are still in the room.
Scan to get
Get it onGoogle Play

People also use

Formula Used
Qtot=b ∑iAiQ_{tot} = b\,\textstyle\sum_i A_i
QtotQ_{tot}
Total cooling load
AiA_i
Each room's floor area (up to four)
bb
Base load rate

How the multi-room ac sizing calculator works

A multi-room sizing adds up the cooling each room needs. This calculator takes the floor area of up to four rooms, multiplies the total by a base load rate and returns the total cooling load. The formula is Q = b × ΣA, where b is the load rate per unit of floor area and ΣA is the sum of the room areas. The result is shown in BTU/h, kW and tons, and the largest single room is listed separately. The page works in ft² and BTU/h per ft² and converts internally, so the metric and US-unit versions agree.

Example with the defaults on this page: three rooms of 215, 160 and 130 ft² total 505 ft². At 35 BTU/h per ft² the total cooling load is 505 × 35 = 17,675 BTU/h, which is 5.18 kW, or 1.47 tons. The largest zone is the 215 ft² room at 215 × 35 = 7,525 BTU/h (2.21 kW). In metric, 505 ft² is 46.9 m², and 35 BTU/h per ft² is 110 W/m².

Adding a fourth room of 100 ft² raises the total to 605 ft² × 35 = 21,175 BTU/h, or 1.76 tons. A single 215 ft² room alone is 7,525 BTU/h, which a single split would cover. A lower rate of 25 BTU/h per ft² for a well-insulated home in a mild climate would cut the 505 ft² example to 12,625 BTU/h, which shows how much the rate matters.

What you enter

You enter the floor area of each room, up to four, and the base load rate. Leave a room at 0 if it is unused, and a blank room counts as unused. The rate is the cooling load per unit of floor area. The default of 35 BTU/h per ft² suits an average home in a warm climate. Use a lower figure for a well-insulated home or a mild climate, and a higher one for a hot climate with a lot of glass or a top-floor room under a roof. The tool refuses a negative area and a blank or zero rate, and asks for at least one room.

Reading the result

The total is a cooling load, which is the heat the system must remove, and it is not the electrical power the unit uses. A unit of 5 kW cooling typically draws roughly a third of that or less in electricity, depending on its efficiency. One ton of cooling is 12,000 BTU/h or 3.517 kW. The largest zone shows the biggest single room, because that room sets the size of the largest indoor head. The configuration line is a prompt: one room suggests a single split, and more than one suggests a multi-split, which is one outdoor unit feeding several indoor heads.

Round the total up to the next size the manufacturer offers, and check the model's connection limits. Do not pick a unit much larger than the load. In the United States, ACCA Manual J is the standard load calculation, and ENERGY STAR warns that an oversized air conditioner costs more, wastes energy and does not cool better. An oversized unit switches on and off often and removes less moisture, so the room can feel cold and damp.

Safe by design

This calculator does the arithmetic of sizing. It deliberately stops at the line a certified installer must sign off. It will never tell you a refrigerant charge, a pipe size, a cable or fuse size, or an electrical connection, because those are regulated design decisions where a wrong number causes injury, fire or equipment failure. Refrigerant handling and installation must be carried out by a certified technician, and this page is not an installation guide.

Assumptions and limits

The tool is a rule of thumb. It applies one load rate to every room, so it does not see glazing, orientation, ceiling height, insulation or the number of people. A west-facing room with a large window can need noticeably more cooling per unit of area than a shaded bedroom, and the flat rate will understate the first and overstate the second. For rooms that differ, use the single-room AC sizing tool, which adds glazing, height, occupancy and sun exposure.

The tool adds the rooms directly and does not apply a diversity factor. In practice the rooms rarely all peak together, so a designer may choose a slightly smaller outdoor unit, but that judgement needs the layout and the climate. It also does not model latent load (moisture), duct losses or the climate's design temperature. Treat the result as a first check on a quote, and ask a qualified installer for a room-by-room calculation before you buy.

Using it with the rest of BuildMetricLab

Pair this estimate with the AC sizing, running cost and duct length calculators to plan the whole system. Every BuildMetricLab tool runs entirely in your browser, with no sign-up. Nothing you type is sent to a server, and the formula is shown on the page so the maths can be audited.

Sources & methodology

Total cooling load = base load rate × the sum of the room floor areas, for up to four rooms. A room entered as 0 or left blank is unused. The base rate is in BTU/h per ft² and the areas in ft²; the page converts them (1 ft² = 0.0929 m²; 1 BTU/h per ft² = 3.155 W/m²) so both unit systems agree. Load in BTU/h is watts ÷ 0.293071, and 1 ton of cooling is 12,000 BTU/h (3.517 kW). The default rate of 110 W/m² is a rule-of-thumb value for an average home in a warm climate, not a measured figure for yours. The 'zones' count is the number of rooms with an area above zero. The configuration line is a simple prompt: one room suggests a single split and more than one suggests a multi-split. The result is a cooling load, which is heat to remove, and not the electrical power the unit draws. The tool does not apply a diversity factor, and does not model glazing, orientation, ceiling height, occupancy or latent load.

Frequently asked questions

Single split or multi-split?

One room suits a single split. Several rooms usually suit a multi-split, which is one outdoor unit feeding several indoor heads. It takes less outdoor space than several singles, but all the rooms share one outdoor unit, and the total of the head capacities can be limited by the outdoor unit's rating. Ask your installer for the connection limits of the model.

Do I add the room loads directly?

For a first estimate, yes. The tool adds each room's load. In practice rooms rarely all peak together, so some designers apply a diversity factor below 1 and choose a slightly smaller outdoor unit. The factor depends on the layout and the climate, so ask your installer rather than assuming one.

Why size the largest zone?

The biggest room sets the largest indoor head and often the longest pipe run, so it is worth seeing separately. A head is chosen for its own room's load, so check that each indoor unit suits its room as well as the total suiting the outdoor unit.

Does this account for glazing per room?

No. It uses a flat load rate per unit of floor area, so it does not see glazing, orientation, ceiling height or the number of people. For rooms with very different glazing or sun, size each with the single-room AC sizing tool, which does include them.

Spotted something off?

Calculations or display — let us know.