Air Conditioning Sizing Calculator (BTU/kW)
Cooling load in BTU and kW for a room
Updated July 12, 2026 · Live
What this tool does
Estimates the cooling load of a room in BTU/h and kW from its floor area, ceiling height, glazing, occupancy and sun exposure.
Enter the room area, ceiling height, glazing area, occupancy and sun exposure; the calculator returns the cooling load in BTU/h and kW.
People also use
Formula Used
Formula Used
This calculator estimates the cooling load of one room in BTU/h and kilowatts from its floor area, ceiling height, glazing, occupancy and sun exposure. It runs in your browser and shows its working, so you can check each step against your own measurements.
How the air conditioning sizing calculator works
The load is the sum of three parts, scaled by how much sun the room gets: Q = (A × b × h + G × 70 + P × 100) × m. A is floor area and b is the base load rate in watts per square metre of floor, which stands in for heat coming through walls, roof and floor. h is a height factor, 1 up to a 2.4 m (7.9 ft) ceiling and ceiling height ÷ 2.4 m above that. G is glazing area at about 70 W per m² of glass (6.5 W, or 22 BTU/h, per ft²). P is the number of people at about 100 W of sensible heat each. m is the sun multiplier: 0.9 for a shaded room, 1.0 for medium and 1.2 for a strongly sunlit one.
The default room is 20 m² (215 ft²) with a 2.4 m ceiling, 4 m² (43 ft²) of glass, two people and medium sun. Fabric is 20 × 110 = 2,200 W, glass adds 4 × 70 = 280 W and the two people add 200 W. The total is 2,680 W, or 2.68 kW. Divide by 0.293071 W per BTU/h and that is 9,145 BTU/h. With strong sun the same room needs 2,680 × 1.2 = 3,216 W (10,973 BTU/h), and fully shaded 2,680 × 0.9 = 2,412 W (8,230 BTU/h). Raise the ceiling to 3.6 m (11.8 ft) and the fabric term grows by 3.6 ÷ 2.4 = 1.5, giving 3,300 + 280 + 200 = 3,780 W (12,898 BTU/h).
What you enter
Floor area and ceiling height come from a tape measure or a floor plan. Glazing is the total area of windows and glass doors in the room, including frames if you only have the overall opening size. Occupancy is the number of people who are normally in the room when it is hot. Sun exposure is a judgement: choose high if the room has large windows facing the sun for much of the day and no external shading, low if it is shaded or faces away from the sun, and medium otherwise. Which side that is depends on your hemisphere, because the midday sun is to the south in the northern hemisphere and to the north in the southern.
The base load rate is the one number you probably do not know. It is the heat gain per unit of floor area through the building fabric. On the US version of this page you enter it in BTU/h per ft², and on the metric version in W/m²; 110 W/m² is the same as about 35 BTU/h per ft². Well-insulated, shaded rooms in mild climates sit near the bottom of the range (60 W/m², 19 BTU/h per ft²). Poorly insulated rooms under a roof in a hot climate sit near the top (200 W/m², 63 BTU/h per ft²). If you do not know, the default is a reasonable middle figure; if the room has always been too hot, move it up.
Reading the result
The headline figure is the cooling load in BTU/h, with the same figure in kW beneath it. One kW is 3,412 BTU/h, and one ton of cooling is 12,000 BTU/h, about 3.5 kW. Sizes are sold in steps, so pick the next standard size above the result rather than the one below. For the 9,145 BTU/h default that is a nominal 12,000 BTU/h (3.5 kW) unit, which is 31% above the load. That is acceptable for a variable-speed inverter unit, which can run at part output, and a poorer choice for a single-speed unit.
Do not round up by much more than one step. An oversized unit cools the air fast, reaches the thermostat setting and switches off before it has removed much moisture, so the room feels cold and clammy. The ENERGY STAR guidance for room air conditioners (a US programme) makes the same point: an oversized unit costs more to buy, wastes energy and does not cool any better.
Safe by design
This tool sizes a cooling load only. It does not cover installing the unit. Handling refrigerant is regulated work in most countries and needs a certified technician: EPA Section 608 certification in the US, and F-gas certification in the UK and EU. The electrical supply should be fitted by a qualified electrician working to your local wiring rules.
Assumptions and limits
This is a rule-of-thumb load, not a heat-gain survey. It does not separate sensible heat from latent heat (moisture), so a room with a lot of humidity or ventilation air will need more than it shows. It does not add kitchen appliances, server racks or other equipment, and it does not model the climate beyond the base rate and sun multiplier that you choose. Glass is a single flat figure, so low-emissivity glazing, blinds and external shading are not distinguished.
For a whole house, or any case where the unit is expensive, a proper calculation is worth paying for. In the US that is ACCA Manual J, which accounts for the local design temperature, orientation, construction and infiltration. The cooling-load chapters of the ASHRAE Handbook: Fundamentals give the underlying method used worldwide. Treat this page as a first estimate before that step.
Using it with the rest of BuildMetricLab
Sizing is the first step in an air-conditioning job. The multi-room sizing calculator adds up several rooms and suggests whether one split system or a multi-split suits, the AC ducting length calculator measures the supply run for a ducted system, and the running cost calculator turns the unit you choose into an annual electricity figure. Every BuildMetricLab tool runs in your browser with no sign-up and nothing sent to a server, and each shows its formula so the maths can be audited.
Sources & methodology
Cooling load Q (W) = (floor area × base rate × height factor + glazing area × 70 W/m² + people × 100 W) × sun multiplier. The height factor is the greater of 1 and ceiling height ÷ 2.4 m; the sun multiplier is 0.9 (low), 1.0 (medium) or 1.2 (high). BTU/h = W ÷ 0.293071. The 70 W/m² glazing and 100 W per person (sensible) figures are rules of thumb consistent with the cooling-load method in the ASHRAE Handbook: Fundamentals, and the base rate is a user input (60-200 W/m², 19-63 BTU/h per ft²) because it depends on construction and climate. Latent load, equipment heat and infiltration are not modelled. Every result is calculated from the values you enter, all inputs are editable, and no time-sensitive prices or rates are embedded.
Frequently asked questions
How many BTU do I need per m²?
A typical base rate for the building fabric is 60-200 W per square meter of floor (about 19-63 BTU/h per ft², or 200-680 BTU/h per m²), with 100-130 W/m² (32-41 BTU/h per ft²) common for an average room. The calculator defaults to 110 W/m² (about 35 BTU/h per ft²) and lets you enter your own rate. It then adds glazing, occupancy and sun exposure on top.
Can an AC unit be too big?
Yes. An oversized unit cools fast then short-cycles, leaving the air cold but clammy because it never runs long enough to dehumidify.
Does glazing matter much?
A lot in a sunny room. Each square meter of glass adds about 70 W in this model (6.5 W, or 22 BTU/h, per ft²), and glass that faces the midday sun with no shading adds more. The sun exposure multiplier (0.9 for shaded, 1.2 for strong sun) captures part of that extra load. Which side gets the sun depends on your hemisphere: south in the northern, north in the southern.
Is this a full survey?
No, it is a sizing estimate. A detailed heat-gain survey such as ACCA Manual J (used in the US) separates sensible and latent loads and models the local design climate, orientation and construction in detail.